Abstract: AS 4032.4:2014 pdf download.Water supply-Valves for the control of heated water supply temperatures Part 4: Thermostatically controlled tapsfor the control of heated water supplytemperatures. (c) The overall block dimensions and the type (e...
AS 4032.4:2014 pdf download.Water supply-Valves for the control of heated water supply temperatures Part 4: Thermostatically
controlled tapsfor the control of heated water supplytemperatures.
(c) The overall block dimensions and the type (e.g. surface mounted or concealed).
(d) Details of the end connectors.
(e) The factory pre-set maximum temperature.
1.6 MARKING
Products complying with this Standard shall be marked with the following information:
(a) Manufacturer’s name, trademark or symbol.
(b) Name or model number of the product.
(c) Identification for traceability in the form of either—
(i) batch identification; or
(ii) individual serial number.
(d) Certification mark.
(e) Controls used 10 vary the temperature of the mixed water shall he permanently marked, to make the etTect of movement understood by the user.
(f) The letter ‘H’, the word ‘HOT’ or a red indicator for the heated water inlet. The letter ‘C’, the word ‘COLD’ or a blue indicator for the cold water inlet.
(g) The number of this Standard (i.e. AS 4032.4).
(h) The maximum working pressure.
(i) For electronic taps, the following shall be included:
(l) Electrical supply information -operating voltage and the rating in amperes or loading in W or VA. Any limitation to the
operation of the product shall also be marked (a.c., d.c., frequency. etc.).
Recommended: