Abstract: AS 5715:2015 pdf download.Uninterruptible power systems (UPS) for roadside devices. 1.3.13 Rated oltage Input or output voltage of the UPS as declared by the manufacturer. 1.3.14 Rated voltage range Input or output voltage range of the UPS...
AS 5715:2015 pdf download.Uninterruptible power systems (UPS) for roadside devices.
1.3.13 Rated oltage
Input or output voltage of the UPS as declared by the manufacturer.
1.3.14 Rated voltage range
Input or output voltage range of the UPS as declared by the manufacturer, expressed b its lower and upper rated voltages.
l.3.l Stand-alone [I5
UPS contained within a dedicated housing.
1.3.16 Stalk bypass telectronic bypass)
Power path (primary or stand-b) alternative to the indirect ac. converter, where control is via an electronic power switch, for
example, a transistor. hyrisior. triac or other semiconductor device or devicc.
1.3.17 Static bypass snitch
UPS switch designed to provide static bypass function.
l.3.l Stored cnerg mode
Operation of the UPS when supplied by the following conditions:
(a) Primary power is disconnected or is out of a given tolerance.
(c) Load is within the given range.
(d) Output voltage is within the given tolerance.
1.3.19 Unlnlerruptible poser system (UPS)
Combination of consertors. switches and energy storage deices (such as batteries). constituting a power system for maintaining
continuity of load power in case of input power failure.