Abstract: ASME A112.19.2:2008 pdf download.Ceramic plumbing fixtures. 8.6.3 Report Static pressure, main and total flush volume, and aftertlow (if any) shall be reported in a format similar to that of Figure A.8. The report shall also indicate whethe...
ASME A112.19.2:2008 pdf download.Ceramic plumbing fixtures.
8.6.3 Report
Static pressure, main and total flush volume, and aftertlow (if any) shall be reported in a format similar to that of Figure A.8. The report shall also indicate whether the trap seal was restored.
8.6.4 Performance
The average water consumption of urinals over the two pressures specified in Table 6 shall not exceed 1.9 pf (0.5 gpf) for high-efficiency urinals or 3.8 LpI (1.0 gpf) br low-consumption urinals. This requirement shall be based on the average of the individual values from the three test sets.
8.7 Tests for non-water-consuming urinals
Non-water-consuming urinals shall be tested in accordance with ASME A112.19.19.
9 Markings, packaging, and installation instructions and other literature
9.1 General
9.1.1
Ceramic plumbing fixtures shall be marked with the manufacturer’s name or registered trademark or, in the case of private labelling, the name of the customer For whom the fixture was manufactured. Additional markings shall be in accordance with Clauses 9.2 to 9.5, as applicable.
9.1.2
Markings shall be permanent, legible, and visible after installation.
9.1.3
Acceptable means of applying permanent markings shall include firing on, etching, sand blasting, stamping with a
permanent (non-water-soluble) ink, and casting in.
Adhesive labels that comply with C22.2 No. 0.15 or UL 969 shall also be considered permanent when placed on a
surface that is not normally submerged in water, The exposure conditions specified in Clause 7.1 of UI 969 shall
apply.
9.2 Non-standard fixtures
9.2.1
Fixtures that require proprietary (i.e., non-standard) components, e.g., supply fittings, waste fittings, or water closet seats, shall indicate, in the packaging or the accompanying literature, that such components are provided
by the manufacturer and shall identify the proper replacement parts.
9.2.2
Fixtures that do not comply with one or more of the dimensional requirements of this Standard shall be marked with an “N” to indicate the non-standard nature of the fixture.
Note: This Clause is not intended to afr to fixtuis that none of the dimensional requnernents of this
Standard.
Recommended: