Abstract: IEC 60317-44:2010 pdf free download.Specifications for particular types of winding wires - Part 44: Aromatic polyimide tape wrapped rectangular copper wire, class 240. Where no specific range of nominal conductor dimensions is given for a t...
IEC 60317-44:2010 pdf free download.Specifications for particular types of winding wires - Part 44: Aromatic polyimide tape wrapped rectangular copper wire, class 240.
Where no specific range of nominal conductor dimensions is given for a test, the test applies to all nominal conductor dimensions
covered by the specification sheet.
Unless otherwise specified, all tests shall be carried out at a temperature from 15 C to 35 C and a relative humidity from 45 % to 75 %. Before measurements are made, the specimens shall be preconditioned under these atmospheric conditions for a time sufficient to allow the specimens to reach stability.
The wire to be tested shall be removed from the packaging in such a way that the wire will not be subjected to tension or
unnecessary bends. Before each test, sufficient wire should be discarded to ensure that any damaged wire is not included in the
test specimens.
4 Dimensions
The dimsions due to the insulation depend upon an agreement between purchaser and supplier. The dimensions In this standard shall
be used as a guide in forming that agreement.
4.1 Conductor dimensions See 4.1 of IEC 6O317-O2.
4.2 Tolerance on conductor dimensions.
Recommended: