Abstract: IEC 60317-32:1997 pdf free download.specifications for particular typesof winding wires - Part 32: Glass-fibre wound, resin or varnish impregnated,bare or enamelled rectangular copper wire, temperature index 155. The enamelled wire shall be...
IEC 60317-32:1997 pdf free download.specifications for particular typesof winding wires - Part 32: Glass-fibre wound, resin or
varnish impregnated,bare or enamelled rectangular copper wire, temperature index 155.
The enamelled wire shall be based on one of the following standards and shall be agreed between purchaser and supplier.
IEC 60317-16:1990, Specifications for particular types of winding wires — Part 16: Polyester enamelled rectangular copper wire.
class 155
IEC 60317-28:1990, Specifications for particular types of winding wires — Part 28: Polyesterimide enamelled rectangular copper
wire, class 180
IEC 60317-29:1990, Specifications for particular types of winding wires — Part 29: Polyester or polyesterimide overcoated with polyamide-imide enamelled rectangular copper wire, class 200
When an enamelled wire is used, it must have a minimum class of 130.
The temperature index of the wire is dependent upon the type of impregnating agent used. The impregnating agent applied to the
glass-fibre should have a minimum temperature index of 155.
Recommended: