Abstract: ASME A112.1002:2020 pdf download.Anti-siphon fill valves for water closet tanks. 3.9 Pressure-relief devices For pressure.releevlng devices, pressure relief shall occur at a pressure of at least 1030 kPa (150 psi), and the relief discharge...
ASME A112.1002:2020 pdf download.Anti-siphon fill valves for water closet tanks.
3.9 Pressure-relief devices
For pressure.releevlng devices, pressure relief shall occur at a pressure of at least 1030 kPa (150 psi), and the relief discharge shall be into the fixture.
Section IV
4 Performance requirements and test methods
4.1 General
Tests shall be conducted in the order in which they are listed in this Standard on one test specimen,
4.2 Preconditlonlng and test conditions
4.2.1 Preconditloning
Before testing, the device shall be conditioned at ambient laboratory conditions for not less than 12 h.
4.2.2 Test conditions
Unless otherwise specified in this Standard, tests shall be conducted at ambient laboratory conditions.
4.3 Test specimen installation
For test purposes, specimens shall be installed in accordance with the manufacturer’s instructions.
4.4 Pressure and temperature tests
4.4.1 Pressure and temperature cycling test
4.4.1.1 Purpose
The purpose of the elevated pressure and temperature cycling test is to
a) evaluate the performance of the device at elevated temperatures and pressures: and
b) ensure that the device has a means for securing the refill tube to the overflow tube and that it remains in
place during the test.
4.4.1.2 Procedure
The elevated pressure and temperature cycling test shall be conducted as follows:
a) Install the specimen In a tank In accordance with the manufacturer’s instructions.
b) The water in the tank may be displaced to accelerate the test, provided the flush volume range given by Clause 4.4.1.2 c) is maintained.
Recommended:
ASME A112.1.2:2012 pdf download ASME 14414:2015 pdf download ASME 30.9:2021 pdf download ASME Y14.1-2020 pdf download